CalculatorsToolsGuides 日本語
BenchFig › Guides › How to combine repeated experiments in one graph (pseudoreplication and SuperPlots)
Experimental design

How to combine repeated experiments in one graph (pseudoreplication and SuperPlots)

When you pool cells or wells from three repeats of an experiment and count each one as n, the P value becomes much smaller than it should be (pseudoreplication). Here is how to decide what n is, and how to draw a SuperPlot that shows cell-to-cell variation and run-to-run reproducibility at once, with numbers you can check.

Updated: BenchFig日本語

What is pseudoreplication?

Pseudoreplication means treating measurements that are not independent as if they were. If you measure 6 cells in each of 3 experiments you have 18 cells, but cells from the same dish on the same day share the medium, the passage, the reagent lot and more. They tend to resemble each other, so 18 cells are not 18 independent experiments.

Statistical tests assume independent data and shrink the standard error as n grows. Counting cells as n therefore lets the number of cells you measured, rather than the size of the effect, decide the P value.

Key points
  • Count n as the unit that received the treatment independently (run, animal, culture)
  • Cells, fields and wells are repeats within that unit: average them first
  • Three experiments means n = 3; if groups were run side by side in each, use a paired test
  • A SuperPlot shows cell variation and run reproducibility in one graph

Example: how much does P change?

Made-up data on neurite length in control and drug-treated neurons: three experiments, six cells per group in each. The overall level differs a little between runs, as it often does in real experiments.

Mean of 6 cells per run.
Control meanDrug meanDifference
Run 157.6 µm36.6 µm21.0 µm
Run 264.4 µm44.1 µm20.3 µm
Run 341.2 µm30.2 µm11.1 µm
AnalysisnResult
t test with cells as n (wrong)18 per groupt(34) = 4.99, P = 1.8 × 10−5
Unpaired t test on run means3 per groupt(4) = 2.19, P = 0.093
Paired t test on run means3 pairst(2) = 5.45, P = 0.032

With cells as n, P = 0.00002 looks like an overwhelming effect; analyzed correctly on run means, P = 0.032 (paired). The size of the difference is the same (about 17.5 µm, 95% CI 3.7 to 31.2 µm), but the confidence in it differs by three orders of magnitude. The paired test gives a smaller P than the unpaired one (P = 0.093) because comparing within each run cancels the day effect, such as run 3 being lower overall.

020406080100ControlDrugNeurite length (µm)****
× Cells as n (SEM)
020406080100ControlDrugNeurite length (µm)Exp 1Exp 2Exp 3*
○ SuperPlot (run means ± SD)
The same data (3 experiments × 6 cells each, made up). Left: treating 36 cells as independent makes P tiny and error bars short. Right: small dots are cells, large symbols are run means, color and shape mark the run. Statistics use run means (n = 3), paired t test.
Combine repeated qPCR runs with sample dataOpen three CFX sample files, compute ΔΔCt for each run, and test on the run means.
Open for free →

How to draw a SuperPlot

The SuperPlot, proposed by Lord et al. (2020, J Cell Biol), overlays every cell’s value with the mean of each run.

  1. Plot cells as small dots, jittered within each group so they do not overlap.
  2. Color (and shape) by run, so run-to-run shifts are visible. Using shapes as well as colors keeps the plot readable for color-blind readers.
  3. Overlay run means as large symbols in the same color and shape, with an outline.
  4. Compute the group summary from run means: the line (mean) and error bar (e.g. SD) come from the three run means. State what the error bar is in the legend (see SD vs SEM vs 95% CI).
  5. Test on run means too, and write “n = 3 independent experiments” and the test used (e.g. paired t test) in the legend.

For three or more groups, use repeated-measures or one-way ANOVA with a multiple-comparison test on run means. In BenchFig, choosing “Match by run” with a run column runs repeated-measures ANOVA on the run means (see choosing a statistical test). For qPCR, compute ΔΔCt within each run, then compare runs on the ΔCt (log) scale (see the ΔΔCt method).

What BenchFig does

Try a SuperPlot on the Graph screenReplace the sample values with your own and the plot and test update instantly.
Open for free →

FAQ

What should I count as n?

The unit to which the treatment was independently applied: experimental runs, animals, separately cultured dishes. Cells in the same dish or replicate wells of the same sample are repeated measurements within that unit and are not n.

I only have two experiments.

With n = 2 a test has almost no power and the variability cannot be estimated. Do at least three runs if you can; otherwise show each run without a test and say so in the legend.

Can I use a mixed-effects model instead of run means?

Yes. A linear mixed model with run as a random effect uses the cell-level information well. With only 3–4 runs, though, the conclusion usually matches a test on run means, which is simpler to explain.

Why a paired test?

If control and treatment were run side by side in each experiment (same day, same passage), pairing removes the overall day-to-day shift. If groups were not matched within runs, use an unpaired test.

Draw a SuperPlot with sample dataAdd a “run” column to the table on the Graph screen: points are colored and shaped by run, and the test uses run means.
Open for free →
Your own data, all the way to the final figure.Loading your files, saving, and journal-ready export (PDF, TIFF, PNG, SVG) are in BenchFig Pro for Windows, updated based on researchers’ requests: ¥3,980/year (2 PCs), with lab and perpetual licenses too.
About the app →

Related guides