CalculatorsToolsGuides 日本語
BenchFig › Guides › ΔΔCt vs the Pfaffl method vs the standard-curve method
qPCR

ΔΔCt vs the Pfaffl method vs the standard-curve method

The three methods differ in how they treat amplification efficiency. ΔΔCt fixes it at 100% (doubling every cycle), Pfaffl corrects with an efficiency measured for each gene, and the standard-curve method reads quantities straight from a dilution series. Computing the same data three ways shows how much it matters.

Updated: BenchFig日本語

The three methods at a glance

ΔΔCt (Livak)PfafflStandard curve
EfficiencyAssumed 100% (E = 2)Measured E for each geneBuilt into the curve
You needTarget and reference CtCt plus each gene’s efficiencyA dilution series on the plate
OutputRatio to controlRatio to controlQuantity per sample, and ratio
Best whenEfficiencies 90–110% and similarEfficiencies differ or are far from 100%Efficiency varies by plate, or quantities are needed
Key points
  • Efficiency from the slope: 10−1/slope − 1 (amplification factor E = 1 + efficiency). A slope of −3.32 is 100%
  • Typical acceptance: 90–110% efficiency and R² ≥ 0.98 (BenchFig flags values outside these)
  • As a rule of thumb, if the two genes differ by more than ~5 points, use Pfaffl or a standard curve instead of ΔΔCt
  • Whatever the method, test on a log scale (ΔCt or log₂ ratio)

Calculating amplification efficiency

Run a 10-fold dilution series, plot Ct against log10(starting quantity) and fit a straight line. At 100% efficiency, 10 times more template comes up log210 ≈ 3.32 cycles earlier, so the slope is −3.32.

efficiency = 10−1/slope − 1  amplification factor E = 10−1/slope = 1 + efficiencySlope −3.32 → 100.1%, −3.587 → 90%, −3.103 → 110%. A shallower slope (closer to 0) gives a higher efficiency.
IL6123456714161820222426283032log₁₀ (starting quantity)CqStd-1: Cq 15.71, log SQ 6.00Std-2: Cq 19.02, log SQ 5.00Std-3: Cq 22.58, log SQ 4.00Std-4: Cq 25.93, log SQ 3.00Std-5: Cq 29.47, log SQ 2.00y = -3.443x + 36.31R² = 0.9999E = 95.2 %
GAPDH1234567141618202224262830log₁₀ (starting quantity)CqStd-1: Cq 14.80, log SQ 6.00Std-2: Cq 18.27, log SQ 5.00Std-3: Cq 21.47, log SQ 4.00Std-4: Cq 24.91, log SQ 3.00Std-5: Cq 28.12, log SQ 2.00y = -3.328x + 34.83R² = 0.9998E = 99.7 %
Example standard curves (five 10-fold dilutions, made-up data). IL6: slope -3.443, efficiency 95.2%. GAPDH: slope -3.328, efficiency 99.7%.

Here IL6 has 95.2% efficiency (factor 1.952) and GAPDH 99.7% (1.997). Both are within 90–110%, but they differ by about 4.5 points. For building the curve, quantifying unknowns and a free Excel template, see the qPCR standard curve guide.

The same data, three ways

Mean Ct values: control IL6 30.10 and GAPDH 18.40; treated IL6 25.60 and GAPDH 18.50. How many times higher is IL6 in the treated group?

ΔΔCt

ΔΔCt = (25.60 − 18.50) − (30.10 − 18.40) = -4.60 → 24.60 = 24.25-fold

Pfaffl

For target and reference separately, take the Ct difference “control − treated” and raise each gene’s own amplification factor to that power.

ratio = EtargetΔCt, target(control − treated)ErefΔCt, ref(control − treated) = 1.9524.501.997-0.10 = 20.280.9332 = 21.73-foldE here is the amplification factor (1 + efficiency). With 100% efficiency, E = 2 and the formula reduces to ΔΔCt.

Standard curve

Convert each Ct to a quantity with its curve (quantity = 10(Ct − intercept)/slope), normalize target to reference, then divide treated by control. The result is 21.73-fold, identical to Pfaffl with the same efficiencies.

Made-up example. Ignoring the efficiency difference, ΔΔCt overestimates by about 10%.
MethodTreated / controlDifference from ΔΔCt
ΔΔCt (E = 2 assumed)24.25—
Pfaffl (measured E)21.73-10.4%
Standard curve21.73-10.4%

Efficiency differences compound with the Ct difference. Even at ΔCt = 4.5 cycles, 95% versus 100% efficiency gives 1.9524.5 ≈ 20.28 versus 24.5 ≈ 22.63, about 10% apart.

Try this calculation with sample dataToggle “Correct for efficiency (Pfaffl)” to compare with ΔΔCt on the spot.
Open for free →

Which method to choose

With any method, test on the log scale rather than on the ratio itself (see “Which values to test” in How to calculate ΔΔCt). For three or more groups, see choosing a statistical test.

FAQ

Why is my efficiency above 100%?

Usually inhibition in the most concentrated dilutions (delayed Ct flattens the slope), pipetting error, or non-specific products such as primer dimers. Check whether dropping the most concentrated points brings it into 90–110%, and look for extra peaks in the melt curve.

Do I need a standard curve on every plate?

For the standard-curve method, yes: standards should be on the same plate. For Pfaffl, an efficiency measured once with the same primers and conditions is often reused. Either way, report the efficiency and how it was obtained.

Do Pfaffl and the standard-curve method give the same result?

If the efficiencies come from the same curves, they are mathematically identical (21.73 in the example below). The standard-curve method also gives a quantity for each sample; Pfaffl only needs the efficiency, not standards on every plate.

How does Pfaffl handle two reference genes?

Compute ErefΔCt for each reference gene and divide by their geometric mean (the qBase approach of Hellemans et al.). BenchFig does this, and in the standard-curve method normalizes to the geometric mean of the reference quantities.

Check efficiency on a sample standard curveThe qPCR screen opens with “Sample: standard curve” (IL6 and GAPDH with 10-fold dilutions). See slope, R² and efficiency, and switch to the Pfaffl correction.
Open for free →
Your own data, all the way to the final figure.Loading your files, saving, and journal-ready export (PDF, TIFF, PNG, SVG) are in BenchFig Pro for Windows, updated based on researchers’ requests: ¥3,980/year (2 PCs), with lab and perpetual licenses too.
About the app →

Related guides

Product and journal names are trademarks or registered trademarks of their respective owners.